Highlight loss (the dot won't print)

High severity

Symptoms

Gradients start abruptly: the 2-3% disappears and a visible step appears

Probable causes

  • The high-ruling or stochastic dot is so small it fails to transfer: miscalibrated plate, insufficient pressure, glazed blanket or very short ink